Shipping & Returns
Most orders ship within 1-2 business days. We stand behind every product — contact us if you're not satisfied.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
Compatibility & What's in the Box
Check the product description for included accessories and device compatibility details.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
Key Specifications
Refer to the product description for full specs including wattage, capacity, dimensions, and compatibility.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
UTE9811+ 600V/20A Harmonic-Analysis Digital Power Meter
Overview
The UNI-T UTE9811+ is a compact single-phase digital power meter measuring 3V – 600V / 5mA – 20A to 1W – 12kW. It performs PLL-synchronized harmonic analysis to the 50th order with THD and crest-factor measurement — built for power-quality and distortion work.
It is built for bench and in-rack power measurement on power-supply, converter and appliance-energy work, with RS-232 and RS-485 for datalogging and integration into automated test.
Choosing Your Model — UTE9800+ Series
The UTE9800+ name covers three distinct compact power meters. Compare the full series before selecting:
| Model | What Sets It Apart | Measurement | V / A Range |
|---|---|---|---|
| UTE9802+ | AC / DC / AC+DC True RMS | True power, V, A, W, PF, Hz | 3V – 600V / 0.5mA – 20A |
| UTE9806+ | Apparent power + V / PF alarm limits | V, A, P, VA, PF, Hz, Vpeak, Apeak | 0.5V – 600V / 0.05mA – 10A |
| UTE9811+ | 50th-order harmonic analysis (PLL) | V, A, W, PF, Hz, THD, CF | 3V – 600V / 5mA – 20A |
The three UTE9800+ models are not a progression — each is a distinct instrument chosen by what you need to measure: mixed-mode true RMS (9802+), limit/alarm testing (9806+), or harmonic and distortion analysis (9811+).
For single-phase high-voltage bench measurement or three-phase work, see the UTE310 Series (600 V / 1000 V single-phase) and the UTE323 Series (3-channel three-phase) — distinct higher-tier instrument lines.
Key Features
- 50th-order harmonic analysis, PLL-synchronized
- THD and crest-factor (CF) measurement
- True power, V, A, W, PF and frequency
- 3V – 600V / 5mA – 20A measurement range, to 1W – 12kW
- Voltage resolution 0.01V; current resolution 1mA
- Measurement bandwidth 40Hz – 70Hz
- RS-232 and RS-485 for datalogging and ATE integration
- 4.3-inch LCD display
UNI-T UTE9811+ Details
50th-Order Harmonic Analysis, PLL-Synchronized
The UTE9811+ performs phase-locked-loop synchronized harmonic analysis to the 50th order, with total harmonic distortion (THD) and crest-factor measurement — the data set for power-quality and distortion assessment on non-linear loads.
RS-232 / RS-485 Communication
Both RS-232 and RS-485 are standard, with SCPI and Modbus support, for datalogging and integration into multi-drop production-line monitoring or an automated test framework.
Compact Bench / In-Rack Form Factor
The compact chassis fits a test bench or an instrument rack and leaves the front-panel reading clear for V, A, W, PF and frequency at a glance during a measurement run.
Applications
Power-Quality & Harmonic Work
PLL-synchronized 50th-order harmonic analysis with THD and crest factor quantifies distortion on rectifier and PFC front ends for power-quality assessment.
Pre-Compliance Distortion Screening
Bench harmonic and THD screening flags distortion problems early in design verification, before formal compliance testing.
Accessories and Family Options
UTE-series test cables and the UTE-M01-US North-American test fixture support safe connection to standard plug loads.
Frequently Asked Questions
How does the UTE9811+ differ from the other UTE9800+ models?
Each UTE9800+ model is a distinct instrument: the UTE9802+ adds AC/DC/AC+DC true-RMS modes, the UTE9806+ adds apparent power and limit alarms, and the UTE9811+ adds 50th-order harmonic analysis. They are chosen by measurement need, not as a tier progression.
Does it have a computer interface?
Yes — RS-232 and RS-485 with SCPI and Modbus support, for datalogging and automated test.
Is this a three-phase meter?
No. The UTE9800+ models are single-phase (1P2W). For three-phase measurement, see the UTE323 Series.
Specifications
| Model Number | UTE9811+ |
| Voltage range | 3V – 600V |
| Current range | 5mA – 20A |
| Power range | 1W – 12kW |
| Voltage resolution | 0.01V |
| Current resolution | 1mA |
| Bandwidth | 40Hz – 70Hz |
| Measurement modes | AC |
| Parameters | V, A, W, PF, Hz, THD, CF |
| Harmonic analysis | 1st – 50th (PLL-synced) |
| Wiring mode | 1P2W |
| Display | 4.3-inch LCD |
| Interface | RS-232 / RS-485 |