Shipping & Returns
Most orders ship within 1-2 business days. We stand behind every product — contact us if you're not satisfied.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
Compatibility & What's in the Box
Check the product description for included accessories and device compatibility details.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
Key Specifications
Refer to the product description for full specs including wattage, capacity, dimensions, and compatibility.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.
UT572 4-Wire Ground Resistance Test Kit
Overview
The UT572 verifies grounding systems using 2-, 3-, and 4-wire earth resistance methods and adds soil-resistivity measurement — so the same kit checks an existing electrode and surveys ground for a new one. It measures across five ranges from 4 Ω to 40 kΩ and is rated CAT III 600 V.
Dual test frequencies (94 Hz / 128 Hz) and disturbance-voltage handling keep readings stable on live sites, and 20 result groups store on-board. It runs on AA batteries for field portability. It's backed by UNI-T's nearly 40 years of test-meter manufacturing.
Key Features
- 2-wire, 3-wire, and 4-wire earth resistance methods
- Soil-resistivity measurement (1 m to 40 m spacing)
- Five ranges: 4 Ω, 40 Ω, 400 Ω, 4 kΩ, 40 kΩ
- Dual test frequencies (94 Hz / 128 Hz) to resist interference
- Disturbance-voltage handling for live-site stability
- 20-group data storage
- CAT III 600 V; AA battery power
UT572 Details
2/3/4-Wire Earth Resistance
The UT572 supports the standard fall-of-potential methods — 2-, 3-, and 4-wire — so you can match the test to the site, from a quick 2-wire check to a 4-wire measurement that removes lead resistance for accuracy on low-ohm electrodes.
Soil Resistivity
Beyond electrode resistance, the UT572 measures soil resistivity over stake spacings from 1 m to 40 m — the survey you need to design a grounding system or lightning-protection scheme before it's installed.
Stable Readings on Live Sites
Dual test frequencies of 94 Hz and 128 Hz and disturbance-voltage handling reject the stray currents and noise common around energized installations, so readings stay repeatable in the field.
Field Use
Five ranges from 4 Ω to 40 kΩ cover everything from a good electrode to high-resistance soil, 20 result groups store on-board, and AA-battery power keeps the kit portable.
Applications
Earth-electrode and grounding-system verification; lightning-protection and substation ground testing; soil-resistivity surveys for new installations; and facility and contractor compliance checks on grounding.
Frequently Asked Questions
Which earth resistance methods does the UT572 support?
2-wire, 3-wire, and 4-wire fall-of-potential methods.
Can it measure soil resistivity?
Yes — over stake spacings from 1 m to 40 m, for grounding-system design.
Does it work near energized equipment?
Dual test frequencies and disturbance-voltage handling keep readings stable around stray currents and noise.
Specifications
| Max Resistance | 4 Ω / 40 Ω / 400 Ω / 4 kΩ / 40 kΩ |
| Accuracy | ±(3% + 5) to ±(3% + 15) depending on range |
| Disturbance Voltage | 50 V DC / 40 Hz to 500 Hz AC |
| Disturbance Frequency | 40 Hz to 500 Hz |
| Soil Resistivity | 4 Ω / 40 Ω / 400 Ω / 4 kΩ / 40 kΩ (1 to 40m spacing) |
| Earth Resistance Methods | 2-Wire, 3-Wire, 4-Wire |
| Test Frequency | 94 Hz / 128 Hz |
| Data Storage | 20 groups |
| CAT Rating | CAT III 600 V |
| Display Type | LCD |
| Battery | 1.5 V LR6 ×8 |
| Weight | 1.1 kg |
| Dimensions | 210 × 175 × 90 mm |